Revisiting the Reliability of the Endoscopy and Sedation-Assisted High-Resolution Esophageal Motility Assessment

Hassan Tariq, Jasbir Makker, Chukwononso Chime, Muhammad Umar Kamal, Ahmed Rafeeq, Harish Patel

Abstract


Background: Esophageal high-resolution manometry (HRM) is performed for evaluation of dysphagia or the pre-operative evaluation before esophageal surgery. The esophageal manometry parameters, interpreted as per the Chicago classification (CC), are meant to be acquired in an awake state. At times, the patient intolerance or inability to traverse the manometry catheter across the esophagogastric junction (EGJ) renders incomplete esophageal motility evaluation; hence, sedation or endoscopy assistance is required. There have been concerns raised regarding the use of sedation and resultant alteration of the manometry parameters. The aims were to study the effects of intravenous sedation on esophageal motility parameters and analyze its impact on outcomes of patients with dysphagia who are intolerant to awake manometry procedure.

Methods: The study population comprised patients who had sedation or the endoscopy assistance for the HRM. The indication for HRM, necessity for the sedation, manometry findings, barium esophagogram results, procedural timings and patient outcomes were reviewed. The diagnostic impact of the 10% correction in integrated relaxation pressure (IRP) was also studied.

Results: There were 14 patients from 179 awake manometry procedures that required the sedation or the endoscopy assistance. The mean age was 60.7 years and there was equal gender distribution. Dysphagia (n = 9) remained the predominant indication for the HRM, followed by the pre-operative evaluation for the esophageal surgery (n = 5). In eight patients, awake manometry failed due to the coiling of the catheter above the EGJ and six patients were intolerant to awake catheter insertion technique. Six patients were diagnosed with achalasia and two with EGJ obstruction. The correction of the possible 10% inflation of the IRP did not alter the final diagnosis in majority except one patient with the EGJ obstruction. The findings of the barium esophagogram corroborated the manometry diagnosis.

Conclusion: Esophageal HRM should be done in awake state as much as possible. Sedation may be a feasible option as against aborting the further workup in patients who fail with current techniques involving awake catheter insertion. However, one needs to be mindful of sedation effects on manometry parameters and interpret results carefully.




Gastroenterol Res. 2019;12(3):157-165
doi: https://doi.org/10.14740/gr1185


Keywords


High-resolution manometry and sedation; HRM in intolerant patients; Esophageal manometry and anesthesia; Reliability of HRM and sedation; Failed awake HRM

Full Text: HTML PDF
 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Gastroenterology Research, bimonthly, ISSN 1918-2805 (print), 1918-2813 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.

This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.gastrores.org   editorial contact: editor@gastrores.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.