Gastroenterol Res
Gastroenterology Research, ISSN 1918-2805 print, 1918-2813 online, Open Access
Article copyright, the authors; Journal compilation copyright, Gastroenterol Res and Elmer Press Inc
Journal website http://www.gastrores.org

Original Article

Volume 11, Number 4, August 2018, pages 305-308


Relationship Between the Intraperitoneal Stent Length in Endoscopic Ultrasound-Guided Hepaticogastrostomy and Surgically Altered Upper Gastrointestinal Anatomy in Patients With Malignant Biliary Obstruction

Koichiro Mandaia, b, Koji Unoa, Kenjiro Yasudaa

aDepartment of Gastroenterology, Kyoto Second Red Cross Hospital, 355-5 Haruobi-cho, Kamigyo-ku, Kyoto 602-8026, Japan
bCorresponding Author: Koichiro Mandai, Department of Gastroenterology, Kyoto Second Red Cross Hospital, 355-5 Haruobi-cho, Kamigyo-ku, Kyoto 602-8026, Japan

Manuscript submitted June 18, 2018, accepted July 2, 2018
Short title: Intraperitoneal Stent Length in EUS-HGS
doi: https://doi.org/10.14740/gr1059w

Abstract▴Top 

Background: Endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) is associated with a relatively high proportion of adverse events, and this is attributable to the lack of standardized protocols and specialized equipment. Although the outcomes of EUS-HGS may differ between patients with and those without surgically altered upper gastrointestinal anatomy, there have been no reports on this topic. The present study aimed to evaluate the efficacy and safety of EUS-HGS using our standardized method and to compare the outcomes between patients with and those without surgically altered upper gastrointestinal anatomy.

Methods: In EUS-HGS, we used a long partially covered metal stent, and we kept the gastric wall pressed with the scope tip until the stent was deployed more than 1 cm inside the working channel of the scope to minimize free space between the liver and gastric wall (the intraperitoneal stent length). A total of 12 patients who underwent EUS-HGS using our method were retrospectively studied. Procedural success and adverse events were evaluated, and the outcomes of EUS-HGS were compared between six patients with and six without surgically altered upper gastrointestinal anatomy.

Results: The procedural success rate was 100%. Additionally, stent migration or dislocation was not noted in any of the patients. The intraperitoneal stent length was significantly greater in patients without surgically altered upper gastrointestinal anatomy than in those with surgically altered upper gastrointestinal anatomy (19.8 mm vs. 11.6 mm; 95% confidence interval, 2.185 - 14.147; P = 0.012).

Conclusions: EUS-HGS using our method was safe. Our findings suggested that special attention should be paid to stent migration or dislocation in patients without surgically altered upper gastrointestinal anatomy.

Keywords: Endoscopic ultrasound-guided hepaticogastrostomy; Intra-channel release; Intraperitoneal stent length; Stent length; Surgically altered upper gastrointestinal anatomy

Introduction▴Top 

Studies have shown that endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) was useful for the treatment of malignant biliary obstruction in patients with endoscopic retrograde cholangiopancreatography (ERCP) failure. However, a previous review article noted that despite the high success rate of EUS-HGS, it was associated with a relatively high rate of adverse events [1], which was attributable to the lack of standardized protocols and specialized equipment.

EUS-HGS is sometimes performed in patients who have undergone upper gastrointestinal surgery. These patients may have tissue adhesion around the stomach. Thus, the rates of success and adverse events with EUS-HGS and the intraperitoneal stent length may differ between patients with and those without surgically altered upper gastrointestinal anatomy. However, there have been no reports on this topic.

At our institution, since October 2014, we have been using a standardized procedure of EUS-HGS in patients with malignant biliary obstruction to prevent adverse events. The present study aimed to evaluate our procedure and compare the outcomes of EUS-HGS between patients with and those without surgically altered upper gastrointestinal anatomy.

Materials and Methods▴Top 

Patients

Patients with biliary obstruction due to a malignant tumor, who underwent EUS-HGS between October 2014 and December 2017 at our institution, were identified from a database and were included in this study.

Endoscopic procedure

All procedures were performed using a convex-type echo endoscope (GF-UCT260; Olympus Medical Systems, Tokyo, Japan) and carbon dioxide insufflator. The left intrahepatic bile duct was punctured from the stomach using a 19-gauge needle (SonoTip; Medi-Globe, Rosenheim, Germany or EZShot3plus; Olympus Medical Systems) under Doppler imaging guidance to avoid any intervening arteries or veins. After aspirating the bile juice, a small amount of contrast medium was injected to visualize the biliary tree. Next, a 0.025-inch guidewire (VisiGlide; Olympus Medical Systems) was inserted into the bile duct through a 19-gauge needle. This needle was subsequently exchanged for an ERCP catheter with a 3.5-Fr tip (PR-V110Q; Olympus Medical Systems) to avoid guidewire shearing. The guidewire was then advanced into the common or right intrahepatic bile duct, and the fistula was dilated using a 6-Fr cystotome (Cysto Gastro Set; Endo-flex, GmbH, Voerde, Germany). Subsequently, an electrosurgical high-frequency generator (ESG-100; Olympus Medical Systems) with the diathermy current set to the cut mode (90 W in pulse-cut slow mode) was used. Finally, we placed a long partially covered metal stent (LP-CMS) from the left intrahepatic bile duct to the stomach.

We used the following approach in all patients to avoid adverse events. First, we marked the gastroesophageal junction with clips before EUS. This allowed us to avoid mediastinitis due to transesophageal drainage, because we could recognize the gastroesophageal junction fluoroscopically. Second, we used a LP-CMS with a diameter of 8 mm, length of 12 cm, and uncovered portion of 1 cm at the distal, intrahepatic end (bare-end type, Niti-S biliary S-type; TaeWoong Medical, Seoul, Korea) to avoid bile leakage after stent placement and stent migration into the peritoneal cavity. Third, we kept the gastric wall pressed with the scope tip until deployment of the stent more than 1 cm inside the working channel conduit of the scope. This stent release method allowed us to avoid creating free space between the liver and gastric wall, enabling the intraperitoneal stent length to be minimized and the intragastric stent length to be extended.

Definitions and outcome measurement

The study was a retrospective, observational case series conducted in a single center. The primary outcome was the procedural success rate of EUS-HGS. The secondary outcomes were procedural time, adverse events, intragastric stent length, and intraperitoneal stent length. For comparison of the outcomes of EUS-HGS between patients with (Group A) and those without (Group B) surgically altered upper gastrointestinal anatomy, the following parameters were additionally evaluated: age, sex, primary diseases, and reasons for EUS-HGS.

We measured the stent lengths of the intragastric and intraperitoneal portions on computed tomography performed more than 48 h after EUS-HGS.

The study was reviewed and approved by the Institutional Review Board of Kyoto Second Red Cross Hospital. All study participants provided informed consent.

Statistical analysis

We used Fisher’s exact test to compare the proportions of categorical variables, such as sex. After confirming homoscedasticity using the F test and normal distribution using the Kolmogorov-Smirnov test, we used Student’s t-test to compare the means of continuous variables, such as age. All statistical analyses were performed using EZR (Saitama Medical Center, Jichi Medical University, Japan), which is a graphical user interface for R (The R Foundation for Statistical Computing, Vienna, Austria) [2]. A P-value < 0.05 was considered to indicate a statistically significant difference.

Results▴Top 

Patient characteristics

Patient characteristics are presented in Table 1. A total of 12 patients (eight men) were analyzed in the present study. The mean patient age was 74.3 years (range, 42 - 93 years). The primary cancers were pancreatic cancer (n = 6), gastric cancer (n = 3), biliary cancer (n = 2), and hepatocellular carcinoma (n = 1). The reasons for EUS-HGS were failed ERCP (n = 6), failed passage of the endoscope due to a malignant duodenal stricture (n = 4), and failed passage of the endoscope due to a malignant afferent loop stricture with recurrence of cancer (n = 2).

Table 1.
Click to view
Table 1. Patient Characteristics
 

EUS-HGS outcomes

The procedural success rate was 100%. Additionally, the mean procedural time was 41.2 min. No adverse events were noted in any of the patients during the procedure and within 30 days after the procedure. Although liver abscess around the stent occurred on postoperative day 32 in one patient, the patient recovered with antibiotic administration and percutaneous transhepatic aspiration. The mean intragastric stent length was 57.4 mm, and the mean intraperitoneal stent length was 15.7 mm (Table 2).

Table 2.
Click to view
Table 2. Outcomes of EUS-HGS
 

Comparison between patients with (Group A) and those without (Group B) surgically altered upper gastrointestinal anatomy

Six patients had surgically altered upper gastrointestinal anatomy, including two who underwent distal gastrectomy with Roux-en-Y reconstruction, two who underwent choledochojejunostomy with Roux-en-Y reconstruction, and two who underwent gastrojejunostomy. There was no stent migration or dislocation, or biliary peritonitis in both groups. Fisher’s exact test showed no significant difference in procedural time between the groups. The intraperitoneal stent length was significantly greater in Group B than in Group A (19.8 mm vs. 11.6 mm; 95% confidence interval, 2.185 - 14.147; P = 0.012) (Table 3).

Table 3.
Click to view
Table 3. Comparison of Outcomes Between Patients With (Group A) and Those Without (Group B) Surgically Altered Upper Gastrointestinal Anatomy
 
Discussion▴Top 

We found that our EUS-HGS approach was safe and that the intraperitoneal stent length was significantly greater in patients without surgically altered upper gastrointestinal anatomy than in those with surgically altered upper gastrointestinal anatomy.

According to the literature, the complication of stent migration to the peritoneal cavity may occur in both the early and late post-EUS-HGS phases and might lead to a very poor prognosis. Reports have presented a case in which a 6-cm covered metallic stent migrated with a fatal outcome and a case in which an 8-cm covered metallic stent migrated, necessitating surgical treatment [3, 4]. Moreover, a recent report described a significantly shorter median stent patency duration in patients who underwent EUS-HGS with an intragastric stent < 3 cm in length than in those who underwent EUS-HGS with an intragastric stent ≥ 3 cm in length [5]; therefore, we believe that stents measuring 10 cm or longer should be used [6].

A recent report showed the efficacy and safety of EUS-HGS using a LP-CMS, but the stent release method was not described in that study [7]. Another recent report showed the efficacy and safety of EUS-HGS with the intra-channel release method, but the stents used in that study were not standardized [8]. In the present study, we evaluated the outcomes of EUS-HGS with the intra-channel release method using the same LP-CMS in all patients.

No studies have compared the outcomes of EUS-HGS between patients with and those without surgically altered upper gastrointestinal anatomy. In the present study, although we used the same stents and released them with the same method, the intraperitoneal stent length was significantly greater in patients without surgically altered upper gastrointestinal anatomy. This may be clinically plausible because we thought that those patients did not have tissue adhesion around the stomach and the stomach wall could be easily moved away from the liver during the procedure. Thus, we should be more careful with regard to stent migration or dislocation when EUS-HGS is performed in patients who have never undergone upper gastrointestinal surgery. This may be important clinical information for EUS-HGS.

The present study has several limitations. This was a single-arm, retrospective study in a single center, and the number of patients was too small to draw solid conclusions. However, this is the first study to compare the outcomes of EUS-HGS between patients with and those without surgically altered upper gastrointestinal anatomy. We were able to compare the intraperitoneal stent length between those patients, because we used the same stents and a standardized release method.

In conclusion, EUS-HGS with the intra-channel release method using a LP-CMS was safe. Our findings suggested that special attention should be paid to stent migration or dislocation in patients without surgically altered upper gastrointestinal anatomy, as the intraperitoneal stent length tended to be long.

Conflict of Interest

All the authors declare no conflict of interest associated with this study.


References▴Top 
  1. Ikeuchi N, Itoi T. Endoscopic ultrasonography-guided biliary drainage: an alternative to percutaneous transhepatic puncture. Gastrointest Interv. 2015;4:31-39.
    doi
  2. Kanda Y. Investigation of the freely available easy-to-use software 'EZR' for medical statistics. Bone Marrow Transplant. 2013;48(3):452-458.
    doi pubmed
  3. Martins FP, Rossini LG, Ferrari AP. Migration of a covered metallic stent following endoscopic ultrasound-guided hepaticogastrostomy: fatal complication. Endoscopy. 2010;42(Suppl 2):E126-127.
    doi pubmed
  4. Okuno N, Hara K, Mizuno N, Hijioka S, Imaoka H, Yamao K. Stent migration into the peritoneal cavity following endoscopic ultrasound-guided hepaticogastrostomy. Endoscopy. 2015;47(Suppl 1 UCTN):E311.
  5. Ogura T, Yamamoto K, Sano T, Onda S, Imoto A, Masuda D, Takagi W, et al. Stent length is impact factor associated with stent patency in endoscopic ultrasound-guided hepaticogastrostomy. J Gastroenterol Hepatol. 2015;30(12):1748-1752.
    doi pubmed
  6. Mandai K, Uno K, Okada Y, Suzuki A, Yasuda K. Endoscopic ultrasound-guided hepaticogastrostomy using a 6-F cystotome and 12-cm covered metal stent. Endosc Int Open. 2016;4(3):E287-291.
    doi pubmed
  7. Nakai Y, Isayama H, Yamamoto N, Matsubara S, Ito Y, Sasahira N, Hakuta R, et al. Safety and effectiveness of a long, partially covered metal stent for endoscopic ultrasound-guided hepaticogastrostomy in patients with malignant biliary obstruction. Endoscopy. 2016;48(12):1125-1128.
    doi pubmed
  8. Uchida D, Kawamoto H, Kato H, Goto D, Tomoda T, Matsumoto K, Yamamoto N, et al. The intra-conduit release method is useful for avoiding migration of metallic stents during EUS-guided hepaticogastrostomy (with video). J Med Ultrason (2001). 2018;45(3):399-403.
    doi pubmed


This article is distributed under the terms of the Creative Commons Attribution Non-Commercial 4.0 International License, which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.


Gastroenterology Research is published by Elmer Press Inc.

 

Browse  Journals  

 

Journal of Clinical Medicine Research

Journal of Endocrinology and Metabolism

Journal of Clinical Gynecology and Obstetrics

 

World Journal of Oncology

Gastroenterology Research

Journal of Hematology

 

Journal of Medical Cases

Journal of Current Surgery

Clinical Infection and Immunity

 

Cardiology Research

World Journal of Nephrology and Urology

Cellular and Molecular Medicine Research

 

Journal of Neurology Research

International Journal of Clinical Pediatrics

 

 
       
 

Gastroenterology Research, bimonthly, ISSN 1918-2805 (print), 1918-2813 (online), published by Elmer Press Inc.                     
The content of this site is intended for health care professionals.

This is an open-access journal distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License, which permits unrestricted
non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Creative Commons Attribution license (Attribution-NonCommercial 4.0 International CC-BY-NC 4.0)


This journal follows the International Committee of Medical Journal Editors (ICMJE) recommendations for manuscripts submitted to biomedical journals,
the Committee on Publication Ethics (COPE) guidelines, and the Principles of Transparency and Best Practice in Scholarly Publishing.

website: www.gastrores.org   editorial contact: editor@gastrores.org
Address: 9225 Leslie Street, Suite 201, Richmond Hill, Ontario, L4B 3H6, Canada

© Elmer Press Inc. All Rights Reserved.


Disclaimer: The views and opinions expressed in the published articles are those of the authors and do not necessarily reflect the views or opinions of the editors and Elmer Press Inc. This website is provided for medical research and informational purposes only and does not constitute any medical advice or professional services. The information provided in this journal should not be used for diagnosis and treatment, those seeking medical advice should always consult with a licensed physician.